300×150 Smart Luminous Zebra Crossing Floor Tile
The 300×150MM smart glowing crosswalk tile is a self-developed traffic product by Wideway, installed on pedestrian crosswalks. Active lighting reminds drivers to yield and warns pedestrians, ideal for urban roads, school crossings and commercial areas. Built with the industry’s only 300×150MM exclusive injection mold with design patent, it delivers superior consistency, cost efficiency and market uniqueness over conventional CNC-made tiles.
Share This Products :
| Low Power, High Brightness | Red mode <2W, green mode 1.95W — outstanding night visibility with energy savings |
| Anti-Slip Tactile Surface | Textured surface prevents slips in rain and provides tactile cues for visually impaired pedestrians |
| IP68 Dual-Layer Waterproof | Dedicated top waterproof layer + wrapped internal sealing for long-term outdoor use |
| Detachable Base | Replace luminous module by removing two side screws — no road excavation, instant repair |
| Exclusive Injection Mold | Industry-unique 300×150MM plastic mold + design patent, one-piece molding, cannot be replicated |
| Reliable Material | Premium engineering plastic, pressure/corrosion/weather resistant for harsh road conditions |
| Lower O&M Costs | No road-breaking, shorter closures, no secondary road damage, fewer municipal approvals |
300x150MM Floor Traffic Light
The 300×150 mm floor tiles for traffic lights are the core components of the smart crosswalk system. They are embedded in the pedestrian waiting areas and on both ends of the crosswalk surface, switching synchronously with the signals from the pole-mounted pedestrian traffic lights. The illuminated floor surfaces provide visual cues to pedestrians regarding their right of way, addressing key traffic safety issues such as looking down at mobile phones, being caught in backlighting, and having difficulty seeing overhead signals at night; they also serve as a reminder to passing motor vehicles to slow down and yield to pedestrians. Red light = no passage; green light = passage permitted. (As shown in the figure below.)
Functions of the 300×150 mm floor tile traffic light product
shiny red:Pedestrians are prohibited from crossing the street; they are reminded to stop and wait, while drivers are warned to be mindful that pedestrians are waiting to cross at the intersection;
bright green:Allow pedestrians to cross and provide a prompt indicating that they may safely cross at the zebra crossing; in certain scenarios, a flashing red light is supported as a countdown warning before the green light ends.
Traffic Order Management:Guide pedestrians to wait within the stop line, thereby curbing running red lights and jaywalking; standardize pedestrian crossing patterns to reduce illegal street-crossing behavior at intersections.
Friendly reminder for smartphone overuse:There is no need to look up at the pole-mounted signal lights; the lights beneath one’s feet provide an intuitive indication of traffic signals, thereby addressing the problem of pedestrians ignoring traffic lights while using mobile phones while crossing the street;
Enhanced recognition in low-light environments:It provides clear visibility at night, during rain, in fog, and against backlighting, thereby addressing the shortcomings of traditional signal lights, which suffer from obstructed visibility and poor visibility; 300x150MM Floor Traffic Light is also suitable for elderly people, children, and individuals with reduced visual acuity, making 300x150MM Floor Traffic Light easier to identify signal lights.
Warning for motor vehicles:Light-emitting LED strips delineate the boundaries of crosswalks, reminding drivers to slow down in advance and yield to pedestrians; they also enable the identification of crosswalk areas from a distance, thereby reducing the risk of collisions between pedestrians and vehicles at intersections. — Zhengzhou Evening News.
300×150 mm floor tiles: traffic lights can address the core pain points faced by customers.
Avoid looking down at your phone and overlooking pedestrian signal lights installed on poles.
Lighting is installed beneath the pedestrians’ feet, so they do not need to look upward; while walking, they can directly receive red or green traffic signals, thereby mitigating the safety hazard faced by smartphone addicts who cannot see traffic lights when crossing the road.
Conventional traffic signals are easily obstructed by large vehicles and trees, and visibility is poor in backlighting conditions or on rainy nights.
A ground-based close-range light source is unaffected by obstructions; 300x150MM Floor Traffic Light provides better visibility in rainy conditions and in low-light nighttime scenes.
Addressing the difficulty for elderly people, children, and people with visual impairments in recognizing signal lights
Broad-area soft illumination provides visual cues, lowers the barrier to recognition, and enhances the safety of vulnerable pedestrians crossing the street.
Road surface equipment has insufficient load-bearing capacity, making 300x150MM Floor Traffic Light susceptible to damage from vehicle traffic and resulting in high long-term maintenance costs.
Designed with a high-strength pressure-bearing shell, 300x150MM Floor Traffic Light can withstand the rolling loads of heavy-duty vehicles, offers a long service life, and reduces the frequency of operation, maintenance, and replacement.
Wiring Instructions for 300×150 mm Floor Tiles and Traffic Lights
DC12V:
1.Blue line: Common positive
2.Yellow line: green negative electrode
3.Red line: negative terminal of the red light
(Note: This is the wiring configuration for a single floor tile traffic light. For a floor tile traffic light covering the entire intersection, simply connect the junction between the two floor tile traffic lights; once all connections have been made, connect the control box.)
Product Installation
Installation of floor tiles and traffic lights:
1. Close off the road and enclose 300x150MM Floor Traffic Light with fencing; ensure that the enclosure is properly installed and that construction warning signs are placed in place to guarantee the safety of personnel working at the site.
2. Confirm the installation position, orientation, and distance of the floor tile traffic lights.
3. Mark the dimensions for the groove and cut a straight groove. (As shown in the figure below.)
4. Slot dimensions: Must accommodate a through-base; the slot dimensions are larger than those of a through-base to facilitate installation and level alignment.
5.Cutting the cable routing groove:
Cable routing cutting involves identifying the optimal position for routing from the traffic light to the steel channel, then cutting a routing groove for a PPR hot-melt circular conduit; the depth from the top of the PPR circular conduit to the ground should be approximately 10 cm. The cut width is 5 cm (depending on the actual number of power cables in each direction at the intersection). Primary function: Ensure a seamless connection between the controller's output port low-voltage power line (DC24V) and the center of the floor tile, with no interfaces allowed.
6.Clear out debris:
Thoroughly clean away all the construction waste that has been cut out; then chisel 300x150MM Floor Traffic Light level below so that i300x150MM Floor Traffic Light can be easily placed into the steel trough and the illuminated paving tiles for the smart zebra crossing. Finally, transport and remove all the waste generated during the process.
7.Install floor tiles:
Place the square channel, whose floor tiles have already been secured, into the excavated groove (before shipment, the manufacturer will fix the floor tiles to the square channel; five floor tiles form one group, and the connection joints are installed; each group has two connection joints in the base at both ends—one connects to the next group, while the other connects to the control box)—then secure it. After positioning the product along this reference level line, level it. Once the smart crosswalk floor tiles have been installed, locate the corresponding outlet along the smart crosswalk. Each direction of every smart crosswalk base has one outlet; align the outlet position with the inlet position.
8.Power-on test:
Connect each completed power cable to the power supply via the control box's output ports (note: never apply 220 V, because the smart zebra crossing is designed for a 24 V DC power supply; applying 220 V to power the smart zebra-crossing lights will directly burn out all the connected devices). Reminder: Please note that this is a low-voltage test; only a 24 V power supply may be used to test this product. Connect the positive and negative terminals of the power supply to the corresponding red terminals of the product, then connect the green terminals to the green terminals, and finally connect the common negative terminals to each other. After confirming that everything is correct, turn on the power supply of the control box.
300x150MM Floor Traffic Light Batch Aging
300x150MM Floor Traffic Light Usage Precautions
This product features an aluminum casing; heavy pressure should be strictly avoided to prevent damage to the casing. The device must be powered on only under the supervision of a qualified professional; do not disassemble or assemble the luminaire without authorization.
300x150MM Floor Traffic Light Warranty Terms
• Warranty Period: 3 years; the warranty covers only the main unit of the lighting fixture; accessories are not covered; custom-made products are excluded.
• Return Method: Customer returns
• Scope of Exclusion: Malfunctions resulting from human-induced damage or natural disasters are not covered under the warranty.
• Logistics Note: The shipping cost for returned items shall be borne solely by the shipper.
| LED configuration | ¢5 round tube LED configuration: ¢5 round tube |
|---|---|
| Single-brick load capacity | greater than 50 t |
| Floor tile dimensions | 300*150*55 mm |
| LED chip category | Taiwan Epistar LED chips |
| Red wavelength | 620–625 nm |
| Green wavelength | 520–525 nm |
| Floor tile shell material | polymer composite material |
| Bottom shell material | electrostatic spray coating; sheet-metal chassis |
| Operating voltage | DC 24 V |
| Average luminous intensity | ≥3000 cd/㎡; no glare and high brightness |
| Viewing distance | 1–100 m |
| Operating temperature | -40 °C to +95 °C |
| Relative humidity | 10%–95% |
| Insulation rating | >1500 V |
| Ground current | ≤3 mA |
| Mean Time Between Failures | ≥10,000 hours |
| Service life | ≥100,000 hours |
| Uniformity | uniform brightness |
| Protection rating | IP68 |
| Installation method | underground |
| fittings of a machine | quantity | Notes |
| ground tile | 1 unit | Red and green dual-color options to meet warning requirements in different scenarios |
| lampstand | 1 unit | Install floor tiles |
| certificate | 1 copy | As a certificate of material release upon qualification |
| product specification | 1 copy | Includes product technical specifications, illustrated installation steps, and a safety and maintenance guide. |